{"id":118,"date":"2025-07-25T11:42:00","date_gmt":"2025-07-25T02:42:00","guid":{"rendered":"https:\/\/www.seiken.co.jp\/english\/wp\/?page_id=118"},"modified":"2025-08-24T19:26:26","modified_gmt":"2025-08-24T10:26:26","slug":"non_magnetic","status":"publish","type":"page","link":"https:\/\/www.seiken.co.jp\/english\/products\/probe\/non_magnetic\/","title":{"rendered":"Non-Magnetic Technology"},"content":{"rendered":"<section id=\"about\" class=\"container\">\n<h2>High-precision testing with minimal magnetic interference<\/h2>\n<div class=\"column2\">\n<div class=\"txt_wrap\">\n<p>As electronic devices become more advanced and compact, the demand for precision testing continues to grow\u2014especially when it comes to components affected by magnetic fields. Traditional testing methods often fall short in these scenarios. That\u2019s where Seiken\u2019s non-magnetic technology comes in.<br \/>By combining carefully selected non-magnetic materials with advanced manufacturing techniques, we deliver probe solutions that minimize magnetic interference and ensure accurate, reliable measurements. Our lineup also includes specialized features such as non-magnetic alloys that resist solder adhesion, and narrow-pitch support using next-generation Kelvin technology\u2014ideal for challenging inspection environments.<br \/>\n              <br \/>Whether you&#8217;re testing electronic compasses, Hall ICs, or MR\/MI sensors, our non-magnetic probes offer some of the most reliable solutions available in Japan. If you&#8217;re looking to minimize the effects of magnetic fields and achieve the highest level of test accuracy, our non-magnetic probes are the ideal choice.<\/p>\n<\/p><\/div>\n<figure>\n            <img decoding=\"async\" src=\"https:\/\/www.seiken.co.jp\/english\/wp\/wp-content\/themes\/wp-seiken-en\/assets\/images\/products\/probe\/non_magnetic\/about_img01.jpg\" alt=\"Non-Magnetic Technology\"><br \/>\n          <\/figure>\n<\/p><\/div>\n<\/section>\n<div class=\"anchor\">\n<ul class=\"anchor_list container\">\n<li><a href=\"#feature\">Key Features &#038; Advantages<\/a><\/li>\n<li><a href=\"#usage\">Application Examples<\/a><\/li>\n<li><a href=\"#cases\">Custom solution examples<\/a><\/li>\n<li><a href=\"#related_products\">Related Products<\/a><\/li>\n<\/ul><\/div>\n<section id=\"feature\" class=\"container\">\n<h2>Key Features &#038; Advantages<\/h2>\n<div class=\"box -border\">\n<h3>01 Top-class low magnetization properties<\/h3>\n<div class=\"column2\">\n<div class=\"txt_wrap\">\n<p>Through material selection and precision processing, we achieve one of the lowest magnetization levels in the industry\u2014greatly reducing magnetic interference and enabling high-accuracy testing.<\/p>\n<\/p><\/div>\n<figure class=\"-border\">\n<div>\n                <img decoding=\"async\" src=\"https:\/\/www.seiken.co.jp\/english\/wp\/wp-content\/themes\/wp-seiken-en\/assets\/images\/products\/probe\/non_magnetic\/feature_img01.jpg\" alt=\"\">\n              <\/div>\n<\/figure><\/div>\n<\/p><\/div>\n<div class=\"box -border\">\n<h3>02 Non-magnetic technology design<\/h3>\n<p>The probe tips are made from non-magnetic precious metal alloys, ensuring stable contact and minimal magnetic influence. These materials also provide excellent connectivity with lead-free solder bumps and Sn-plated terminals.<\/p>\n<\/p><\/div>\n<div class=\"box -border\">\n<h3>03 Flexible probe layouts<\/h3>\n<div class=\"column2\">\n<div class=\"txt_wrap\">\n<p>Enjoy all the benefits of spring probes while adapting to area arrays and custom pin configurations. Our solutions allow for highly flexible test setups tailored to your design.<\/p>\n<\/p><\/div>\n<figure>\n              <img decoding=\"async\" src=\"https:\/\/www.seiken.co.jp\/english\/wp\/wp-content\/themes\/wp-seiken-en\/assets\/images\/products\/probe\/non_magnetic\/feature_img02.jpg\" alt=\"\"><br \/>\n            <\/figure>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"box -border\">\n<h3>04 Adaptable to fine-pitch, short probes<\/h3>\n<div class=\"column2\">\n<div class=\"txt_wrap\">\n<ul class=\"list -dotted\">\n<li>Minimum probe diameter: \u03a690\u03bcm<\/li>\n<li>Minimum pitch: 150\u03bcm<\/li>\n<li>Shortest overall length: 3.25mm (for 300\u03bcm pitch)<\/li>\n<\/ul><\/div>\n<figure>\n              <img decoding=\"async\" src=\"https:\/\/www.seiken.co.jp\/english\/wp\/wp-content\/themes\/wp-seiken-en\/assets\/images\/products\/probe\/non_magnetic\/feature_img03.jpg\" alt=\"Fine-pitch probe\"><br \/>\n            <\/figure>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"box -border\">\n<h3>05 Non-magnetic customization available for catalog products<\/h3>\n<p>Many of our catalog-listed probes can be customized with non-magnetic materials. We\u2019re happy to accommodate special requests.<br \/>\n<br \/>*Please note that production may require additional lead time.<\/p>\n<\/p><\/div>\n<\/section>\n<section id=\"usage\" class=\"container\">\n<div class=\"ttl_link\">\n<h2>Application Examples<\/h2>\n<p>          <a href=\"..\/..\/industry_category\/\" class=\"link\"><span>Explore more <\/span><\/a>\n        <\/div>\n<div class=\"column2\">\n<figure class=\"-border\">\n<div><img decoding=\"async\" src=\"https:\/\/www.seiken.co.jp\/english\/wp\/wp-content\/themes\/wp-seiken-en\/assets\/images\/products\/probe\/non_magnetic\/usage_img01.jpg\" alt=\"\"><\/div>\n<\/figure>\n<div class=\"txt_wrap\">\n<ul class=\"list -dotted\">\n<li>Electronic compasses<\/li>\n<li>Hall ICs<\/li>\n<li>MR \/ MI sensors<\/li>\n<li>Any application sensitive to magnetic interference<\/li>\n<\/ul><\/div>\n<\/p><\/div>\n<\/section>\n","protected":false},"excerpt":{"rendered":"<p>High-precision testing with minimal magnetic interference As electronic devices become more advanced and compa [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":39,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-products-child.php","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-118","page","type-page","status-publish","hentry"],"aioseo_notices":[],"acf":[],"_links":{"self":[{"href":"https:\/\/www.seiken.co.jp\/english\/wp-json\/wp\/v2\/pages\/118","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.seiken.co.jp\/english\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.seiken.co.jp\/english\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.seiken.co.jp\/english\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.seiken.co.jp\/english\/wp-json\/wp\/v2\/comments?post=118"}],"version-history":[{"count":0,"href":"https:\/\/www.seiken.co.jp\/english\/wp-json\/wp\/v2\/pages\/118\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.seiken.co.jp\/english\/wp-json\/wp\/v2\/pages\/39"}],"wp:attachment":[{"href":"https:\/\/www.seiken.co.jp\/english\/wp-json\/wp\/v2\/media?parent=118"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}